The CDMS interface is implemented in the Controller's FPGA. It complies with the CDMS interface definition (REID-A)1. A non-redundant RIU in intelligent / non-redundant units with hardware decoded HK delivery implementation was chosen for ADS. The specific ADS CDMS address is 5 (00101B). If the subsystem is addressed by CDMS, then the CIU interprets the following four cases by hardware:
The ADS software manages the CDMS requests by interrupt and formats and outputs a status word. After that it gives control to three corresponding user callback routines to handle the CDMS request.
The QM needs 28 V power source direct from the primary bus. The current is measured by the QM itself. The measurement circuit is similar to the circuits on the Electronic Interface Board.
Typical power consumption at 25 C, see table 13.
|